GT-500 copper connecting tube

GT-500 copper connecting tube

(1 đánh giá)

Đầu nối ống đồng GT-500

GT-500 copper connecting tube is a passing-through connector designed for joining two conductor ends in a straight-line connection using a suitable crimping method. The product has a copper tubular body with an outside diameter D of 38 mm, an inside diameter d of 30 mm and an overall length L of 150 mm.

Specification Value
Model GT-500
Connector type Passing-through straight tube
Material Copper
Outside diameter D 38 mm
Inside diameter d 30 mm
Overall length L 150 mm

Before ordering, check the actual conductor dimensions, conductor material, crimping tool and die set. Do not select the connector by model name alone. Send Trường Phát the required model, quantity and delivery information for specification checking and a quotation.

Where two conductor ends must be joined along the same axis, the GT-500 copper connecting tube provides a straight tubular connection point for a suitable crimping process. According to the supplied catalog, the GT-500 has a 38 mm outside diameter, a 30 mm inside diameter and a total length of 150 mm. These dimensions must be checked against the actual conductor, crimping die and installation requirements before the product is used.

What is the GT-500 copper connecting tube used for?

The GT-500 belongs to the group of passing-through copper jointing tubes. Unlike a bolted cable lug, which has a palm and bolt hole for connection to a busbar or equipment terminal, this product has a straight tubular construction. It is intended for joining two conductor ends in line rather than terminating a cable onto a bolt.

During installation, one conductor end is inserted from each side of the tube. The connection is then formed with a compatible crimping tool and die according to the approved installation procedure. The completed connection depends not only on the tube itself but also on correct product selection, conductor preparation, die compatibility and proper workmanship.

The catalog identifies the product by model and dimensions D, d and L. The GT-500 model designation should not be treated as the actual core diameter. A conductor's nominal cross-sectional area and its measured core diameter are different parameters and must be checked separately.

GT-500 dimensions and construction data

Item Symbol Specification
Catalog number Cat.No. GT-500
Connector construction - Passing-through straight copper tube
Outside diameter D 38 mm
Inside diameter d 30 mm
Overall length L 150 mm
Tube material - Copper

In the catalog drawing, D indicates the outside diameter of the tube, d indicates the internal bore diameter and L indicates the full product length. These three values are useful when checking installation space, conductor insertion and compatibility with the selected crimping system.

Construction features and suitable applications

The GT-500 has a straight cylindrical body without a bolt palm or terminal hole. The supplied drawing also shows an open passing-through construction rather than a bolted termination design. This allows conductors to be inserted from opposite ends when preparing an in-line cable joint.

  • Designed for straight-line joining rather than bolted cable termination.
  • The 150 mm body length provides space for conductor insertion and the crimping area.
  • The 38 mm outside diameter must be considered when choosing a die and arranging the final insulation layer.
  • The 30 mm inside diameter must be compared with the measured size of the prepared conductor bundle.
  • The copper tube must not be used to connect an aluminium conductor directly unless a suitable transition connector is specified.

The GT-500 copper jointing tube may be considered for new cable installation, cable extension or repair of an in-line connection point. Its suitability for a particular project must still be determined from the conductor material, actual dimensions, engineering documents and approved installation method.

Checks to complete before selecting GT-500

Verify the model and all three catalog dimensions

The GT-500 catalog row specifies D 38 mm, d 30 mm and L 150 mm. When receiving the product, check both the catalog number and the dimensions. This helps prevent confusion with GT-400, which is smaller, or GT-630, which has larger listed dimensions.

Confirm the conductor material

The product is described as a copper connecting tube. The conductor material must therefore be identified before installation. A copper tube should not be used for a direct copper-to-aluminium connection without a suitable transition solution. Where different conductor materials are involved, use the connector type specified by the electrical design.

Measure the actual conductor instead of relying only on nominal area

Nominal cross-sectional area does not represent the actual diameter of the conductor core. The measured diameter can vary with conductor construction and strand arrangement. Before ordering a large quantity, compare the cable technical data or physical conductor measurements with the GT-500 internal diameter of 30 mm.

Check the crimping tool and die set

The crimping die must be compatible with both the connector and the tool system. Do not select a die only from the outside diameter. Crimping force, die code, number of compression points and compression sequence must not be assumed when the relevant technical instructions are unavailable.

When requesting a quotation, provide the tool model and die identification where possible. This information supports a more accurate compatibility check before the connectors are supplied for installation.

Preparation, crimping and electrical safety

  1. Disconnect and isolate the electrical supply before beginning work.
  2. Confirm that the circuit is de-energised using the approved safety procedure.
  3. Check the GT-500 model, tube condition and listed dimensions.
  4. Confirm that both conductor ends have suitable materials, construction and dimensions.
  5. Prepare each conductor end according to the approved project procedure without damaging or cutting conductor strands.
  6. Insert the conductors from opposite ends to the positions specified in the installation method.
  7. Use a compatible crimping tool and die set.
  8. Apply the crimping sequence specified by the tool supplier, engineering design or approved work instruction.
  9. Inspect the compressed areas and verify the mechanical stability of the connection.
  10. Apply the required insulation and external protection before the circuit is energised.

The supplied catalog does not state the insulation stripping length, crimping force, die number or required number of compression points for the GT-500. These installation values should not be estimated from the 150 mm tube length. The installer must refer to the approved engineering procedure and the technical instructions for the crimping system.

Frequently asked questions about GT-500

What is the inside diameter of the GT-500?

The catalog specifies an inside diameter d of 30 mm. This is the bore diameter of the connector tube, not the nominal conductor diameter.

What is the total length of the connector?

The listed overall length L is 150 mm. The installation layout should also allow enough working space for the die and the final insulation system.

Can GT-500 be replaced with GT-400 or GT-630?

The models should not be substituted only because they belong to the same product range. Each model has different outside diameter, inside diameter and length values. Any replacement must be checked against the conductor, die system and electrical design.

Is the GT-500 a bolted cable lug?

No. The catalog shows the GT-500 as a passing-through straight connecting tube. It does not have a palm or bolt hole for connection to a busbar or equipment terminal.

Can the GT-500 be used directly with aluminium conductors?

A copper tube should not be used for direct connection to aluminium conductors unless an approved transition solution is provided. The conductor material and connector type must be checked before installation.

How many crimping points are required?

The supplied catalog does not specify the number of compression points. The quantity, position and sequence of crimps must follow the approved die, tool or installation instructions.

Request a quotation for the GT-500 copper connecting tube

To request pricing for the GT-500 copper connecting tube, provide the required model, quantity and conductor information. Trường Phát can check the catalog dimensions of D 38 mm, d 30 mm and L 150 mm before responding with supply information.

Where a specific hydraulic crimping tool or die set is already being used on site, include its model number or identification image with the enquiry. Providing the conductor material, actual dimensions and delivery location also helps reduce the risk of selecting an unsuitable connector.


CÔNG TY TNHH THIẾT BỊ CƠ ĐIỆN TRƯỜNG PHÁT

📍 Số 47, Liền kề 26, KĐT Văn Phú, P. Phú La, Hà Đông, Hà Nội

📞 Hotline:

🌐 phukientudien.com.vn | codientruongphat.com — 📧 kinhdoanh3@truongphatme.com

Đánh giá sản phẩm

Bình chọn sản phẩm:

Sản phẩm cùng loại

GT-630 copper connecting tube NEW

GT-630 copper connecting tube

GT-630 copper connecting tube is a straight-through jointing sleeve used to connect two copper cable ends by compression. The model has a 45 mm outer diameter, a 35 mm inner diameter and an overall length of 170 mm. Its open-ended tubular construction allows conductors to be inserted from both sides before compression with a suitable crimping tool and die set.

Specification Value
Product type Copper connecting tube
Model GT-630
Connection type Straight-through compression joint
Material Copper
Outer diameter D 45 mm
Inner diameter d 35 mm
Overall length L 170 mm

Before ordering, check the actual conductor dimensions, conductor material and the die set used for installation. Do not select the product solely by its model number. Provide the required model, quantity and cable information for dimensional verification and a suitable quotation.

GT-400 copper connecting tube NEW

GT-400 copper connecting tube

The GT-400 copper connecting tube is a straight through-type connector used to join two copper cable ends by compression. This model has an outer diameter D of 34 mm, an inner diameter d of 26 mm and an overall length L of 130 mm. Its tubular construction allows the two prepared conductors to be inserted from opposite ends before compression with a compatible crimping tool and die.

Specification Value
Model GT-400
Product type Straight copper connecting tube
Material Copper
Outer diameter D 34 mm
Inner diameter d 26 mm
Overall length L 130 mm

Before ordering, check the actual conductor dimensions, cable material, die model and operating range of the crimping tool. Do not select the connector only by the cable’s overall outside diameter. Send the model, quantity and cable details to Truong Phat for specification checking and quotation support.

GT-300 copper connecting tube NEW

GT-300 copper connecting tube

The GT-300 copper connecting tube is a passing-through sleeve designed for inline cable jointing by compression. Its open tubular structure allows conductors to be inserted from opposite ends before the connection is compressed with a compatible tool and die. The model is identified by its catalogue dimensions, which should be checked against the actual conductor and the selected installation equipment.

Specification Value
Catalogue number GT-300
Product type Copper connecting tube, passing-through type
Outer diameter D 30 mm
Inner diameter d 24 mm
Overall length L 120 mm

Before ordering, compare the tube dimensions with the conductor, compression die and crimping tool used on site. Send Trường Phát the model, required quantity and cable details for product selection support and a quotation.

GT-240 copper connecting tube NEW

GT-240 copper connecting tube

GT-240 copper connecting tube is a through type copper connector designed for connecting suitable copper cables in electrical installation works. This model belongs to the GT Copper Connecting Tube (Passing Through Type) series, with dimensions of D 26mm, inner diameter d 21mm and length L 108mm according to the product catalog.

Specification Value
Model GT-240
Product type Copper Connecting Tube (Passing Through Type)
Outer diameter D 26 mm
Inner diameter d 21 mm
Length L 108 mm
Series GT-10 to GT-630

Before installation, check the cable cross-section and connection requirements to select the suitable connecting tube. Contact Truong Phat for consultation based on your cable specifications and quantity requirements.

GT-185 copper connecting tube NEW

GT-185 copper connecting tube

GT-185 copper connecting tube is a straight-through sleeve designed to join two 185mm² copper cable conductors by crimping. According to the catalog, the product has a 24 mm outer diameter, 19 mm inner diameter and 100 mm overall length.

Before installation, verify the cable cross-sectional area and actual conductor diameter against the tube bore, then select a compatible crimping tool and die. Do not use this copper tube to connect aluminum conductors directly. Contact Trường Phát with the required model, quantity and cable details for specification checking and quotation support.

GT-150 copper connecting tube NEW

GT-150 copper connecting tube

GT-150 copper connecting tube is a straight, pass-through connector designed to join two compatible copper cable ends by crimping. According to the dimensional table, the connector has a 22mm outer diameter, a 17mm inner diameter and an overall length of 94mm.

Before selection, compare the actual conductor diameter with the 17mm internal bore instead of treating the nominal cable cross-section as the conductor diameter. The conductor material, connector condition, crimping tool and die compatibility should also be checked before installation. Send the GT-150 model, cable details and required quantity to Truong Phat for specification checking and quotation support.

GT-120 Copper Connecting Tube

GT-120 Copper Connecting Tube

GT-120 Copper Connecting Tube is a through-type tubular connector designed to join two conductor ends using a suitable crimping method. According to the supplied dimensional chart, model GT-120 has an outer diameter D of 19mm, an inner diameter d of 15mm and an overall length L of 90mm.

Before selection, compare the actual conductor diameter with the 15mm internal bore and use a compatible crimping tool and die. Do not determine the suitable cable size from the model number alone. Submit the conductor type, actual core dimensions and required quantity for specification checking and quotation.

GT-95 Copper Connecting Tube

GT-95 Copper Connecting Tube

GT-95 Copper Connecting Tube is a passing through type copper cable connector used for electrical cable connection applications. This product belongs to the GT Copper Connecting Tube series, model GT-95, with technical dimensions including outer diameter D 18 mm, inner diameter d 14 mm and length L 81 mm.

Contact Truong Phat for consultation on selecting suitable cable connection accessories.

GT-70 copper connector

GT-70 copper connector

GT-70 copper connecting tube, full catalog number GT-1-70, is a passing-through straight connector designed for inline cable joints. According to the supplied dimensional table, the product has a 16 mm outer diameter, 12 mm inner diameter and 78 mm overall length.

  • Catalog number: GT-1-70
  • Design: Passing-through connecting tube
  • Outer diameter D: 16 mm
  • Inner diameter d: 12 mm
  • Overall length L: 78 mm
GT-50 copper connector

GT-50 copper connector

GT-50 copper connector is a through-type straight connecting tube designed to join two copper cable ends with a suitable nominal cross-sectional area of 50mm² by crimping. The model shown in the dimensional table is GT-1-50, with an outer diameter D of 13mm, an inner diameter d of 10mm and a length L of 70mm.

  • Model: GT-50
  • Suitable cable cross-sectional area: 50mm²
  • Outer diameter D: 13mm
  • Inner diameter d: 10mm
  • Length L: 70mm
GT-35 Copper Connecting Tube

GT-35 Copper Connecting Tube

GT-35 Copper Connecting Tube
GT-35 Copper Connecting Tube features an outer diameter of 11mm and inner diameter of 8mm
🏭 Overall tube length: 63mm, suitable for 35mm² copper cables
🛡️ Through-type construction allows easy positioning of both cable ends before crimping
🔧 Installed using a hydraulic crimping tool with the correct 35mm² die
📦 Multiple GT copper connector sizes are available for switchboards, factories, and projects
👉 Contact Truong Phat for stock checking, quotations, and suitable crimping die recommendations.

TRUONG PHAT ELECTROMECHANICAL EQUIPMENT COMPANY LIMITED
📍 No. 47, Adjacent Area 26, Van Phu Urban Area, Phu La, Ha Dong, Hanoi, Vietnam
📞 Hotline:

 

GT-25 Copper Connector

GT-25 Copper Connector

GT-25 Copper Connector Genuine
🔋 Suitable conductor size: 25mm²
GT-25 copper connector made from T2 copper with Cu content ≥ 99.9%
🏭 Reference dimensions: d = 7.1mm, D = 10mm, L = 60mm
🛡️ Through-hole design allows two cable ends to meet at the center of the tube
🔧 Installed using a mechanical or hydraulic crimping tool with the correct die size
📦 Suitable for switchboards, power cable systems and industrial electrical installations
👉 Contact Truong Phat to check availability and receive the latest GT-25 copper connector quotation. TRUONG PHAT ELECTROMECHANICAL EQUIPMENT COMPANY LIMITED