GT-185 copper connecting tube

GT-185 copper connecting tube

(1 đánh giá)

đầu nối đồng GT-185

GT-185 copper connecting tube is a straight-through sleeve designed to join two 185mm² copper cable conductors by crimping. According to the catalog, the product has a 24 mm outer diameter, 19 mm inner diameter and 100 mm overall length.

Before installation, verify the cable cross-sectional area and actual conductor diameter against the tube bore, then select a compatible crimping tool and die. Do not use this copper tube to connect aluminum conductors directly. Contact Trường Phát with the required model, quantity and cable details for specification checking and quotation support.

Where two cable sections must be joined in line without using a bolted terminal lug, the GT-185 copper connecting tube provides a straight-through crimp connection. The sleeve accepts conductors from both ends and is installed using a suitable mechanical or hydraulic crimping tool. According to the supplied catalog, model GT-185 has a 24 mm outer diameter, 19 mm inner diameter and 100 mm overall length.

This product is a straight cable joint sleeve, not a bolted cable lug. It is therefore intended for joining copper cable to copper cable rather than terminating a conductor directly onto a busbar, MCCB terminal or equipment stud.

What is the GT-185 copper connecting tube used for?

The primary function of GT-185 is to create an in-line joint between two compatible copper cable conductors. Each stripped conductor is inserted from one end of the tube, after which the sleeve is compressed with a suitable crimping tool and die.

The product may be considered for cable extension work, replacement of a damaged cable section or connection of two matching copper conductors. Actual suitability also depends on conductor material, strand construction, conductor diameter after insulation removal and the technical requirements of the electrical system.

  • Joining two compatible copper cable conductors in a straight line.
  • Extending a copper cable route during installation or repair work.
  • Creating an in-line crimped joint along the cable axis.
  • Connecting cables where no bolted palm or mounting hole is required.

GT-185 must not be treated as an SC or DT cable lug for direct connection to equipment. Where a bolted connection is required, select a cable lug with the correct palm shape and stud-hole diameter.

GT-185 dimensions and specifications

Specification Symbol Value
Model Cat.No. GT-185
Suitable nominal cable cross-section - 185mm²
Outer diameter D 24 mm
Inner diameter d 19 mm
Overall length L 100 mm
Connection type - Straight-through connecting tube
Installation method - Crimping with a suitable tool

The D, d and L values are taken directly from the GT-185 row in the supplied catalog. The 19 mm inner diameter is the tube bore, not the actual conductor diameter of every 185mm² cable. Cables with the same nominal cross-sectional area may have different strand constructions and finished conductor diameters, so the cable datasheet or actual conductor size should be checked before ordering.

Straight-through construction and suitable applications

The GT series is identified by its straight cylindrical body, two open ends and absence of a bolted palm. This construction allows conductors to be inserted from opposite directions while keeping the finished joint aligned with the cable route.

With an overall length of 100 mm, GT-185 provides space for inserting both conductors and forming the crimped connection. However, the supplied catalog does not specify stripping length, crimping force, number of crimps or crimping positions. These values must not be assumed and should instead follow the approved installation procedure, cable construction, die system and crimping equipment instructions.

Situations where GT-185 may be suitable

  • Both conductors are copper cables.
  • The required nominal cable cross-section is 185mm².
  • The installation requires a straight sleeve rather than a bolted terminal lug.
  • A compatible crimping tool and die are available.
  • The installation includes suitable insulation and mechanical protection after crimping.

Do not use the GT-185 copper tube to connect an aluminum conductor directly. For aluminum cable or copper-to-aluminum transition joints, use a connector specifically designed for the relevant conductor materials.

How to verify the correct connector before ordering

Model selection should not be based only on the 185mm² marking. The cable specification, tube bore and installation conditions must also be checked.

  1. Confirm the conductor material: GT-185 is a copper connecting tube and is intended for a compatible copper cable connection. It must not be used directly with aluminum conductors.
  2. Check the nominal cross-sectional area: verify the 185mm² rating from the cable marking or technical documentation.
  3. Compare the conductor diameter: the catalog lists a 19 mm tube bore. Confirm that the stripped conductor fits correctly without excessive looseness or forced insertion.
  4. Check installation space: the connector is 100 mm long and 24 mm in outer diameter. Additional working space is required for the crimping tool and final insulation system.
  5. Check the crimping equipment: the die must be compatible with the sleeve type, tube dimensions and cable conductor. Do not select a die only by visual appearance.

For cable terminations that require a bolted palm, refer to the SC copper cable lug range or the DT copper cable lug range. These products are used for equipment termination and must not be confused with the GT-185 straight connecting tube.

Preparation, crimping and safety checks

Cable jointing must only be performed after the circuit has been isolated and verified as de-energized. Installers should use appropriate protective equipment, approved tools and the electrical safety procedure applicable to the project.

  1. Disconnect and isolate the power supply, then verify the absence of voltage.
  2. Confirm the GT-185 model and inspect the tube for deformation, contamination or physical damage.
  3. Prepare both cable ends and remove any damaged conductor section.
  4. Strip the insulation according to the approved installation procedure.
  5. Insert the copper conductors from opposite ends and verify their positions before crimping.
  6. Use a compatible crimping tool and die to form the connection.
  7. Inspect the mechanical stability, crimped surface and conductor condition.
  8. Apply an insulation and protection system suitable for the voltage level, environment and project requirements.

Do not independently specify the crimping force, number of crimps, crimping positions or stripping length without applicable technical instructions. Do not grind down the conductor to make it fit and do not add loose conductor strands to compensate for an incorrectly sized connector.

Frequently asked questions about GT-185

Is GT-185 a bolted cable lug?

No. GT-185 is a straight-through connecting tube with two open ends and no mounting hole. It joins two cable conductors, whereas SC or DT cable lugs terminate a conductor onto a busbar, MCCB or equipment stud.

Is the 19 mm inner diameter the actual diameter of every 185mm² conductor?

No. The 19 mm value is the internal diameter of the tube. The actual conductor diameter depends on the strand construction and cable design.

Can GT-185 be used with aluminum cable?

Do not use this copper tube to connect aluminum conductors directly. Select a connector designed for aluminum cable or for a copper-to-aluminum transition.

Can GT-150 or GT-240 replace GT-185?

They should not be substituted solely because their appearance is similar. GT-150 and GT-240 have different bore diameters, outer diameters and lengths, which may make them incompatible with a 185mm² cable.

How many crimping points are required for GT-185?

The supplied catalog does not state the number of crimps. This must be determined from the cable type, crimping tool, die system and approved installation procedure.

What information should be provided when requesting a quotation?

Provide the GT-185 model, required quantity, conductor material, nominal cable cross-section, actual conductor diameter where available and the crimping tool or die system being used.

Request a quotation for GT-185 copper connecting tube

To request a quotation for the GT-185 copper connecting tube, send the required quantity, copper cable specification, dimensions to be checked and delivery location. Trường Phát can help verify the catalog dimensions of D 24 mm, d 19 mm and L 100 mm, while also confirming that a straight connecting tube is required instead of a bolted cable lug.

Customers may also view the copper and aluminum cable lug category or submit an inquiry through the Trường Phát contact page.


CÔNG TY TNHH THIẾT BỊ CƠ ĐIỆN TRƯỜNG PHÁT

📍 Số 47, Liền kề 26, KĐT Văn Phú, P. Phú La, Hà Đông, Hà Nội

📞 Hotline:

🌐 phukientudien.com.vn | codientruongphat.com — 📧 kinhdoanh3@truongphatme.com

Đánh giá sản phẩm

Bình chọn sản phẩm:

Sản phẩm cùng loại

GT-630 copper connecting tube NEW

GT-630 copper connecting tube

GT-630 copper connecting tube is a straight-through jointing sleeve used to connect two copper cable ends by compression. The model has a 45 mm outer diameter, a 35 mm inner diameter and an overall length of 170 mm. Its open-ended tubular construction allows conductors to be inserted from both sides before compression with a suitable crimping tool and die set.

Specification Value
Product type Copper connecting tube
Model GT-630
Connection type Straight-through compression joint
Material Copper
Outer diameter D 45 mm
Inner diameter d 35 mm
Overall length L 170 mm

Before ordering, check the actual conductor dimensions, conductor material and the die set used for installation. Do not select the product solely by its model number. Provide the required model, quantity and cable information for dimensional verification and a suitable quotation.

GT-500 copper connecting tube NEW

GT-500 copper connecting tube

GT-500 copper connecting tube is a passing-through connector designed for joining two conductor ends in a straight-line connection using a suitable crimping method. The product has a copper tubular body with an outside diameter D of 38 mm, an inside diameter d of 30 mm and an overall length L of 150 mm.

Specification Value
Model GT-500
Connector type Passing-through straight tube
Material Copper
Outside diameter D 38 mm
Inside diameter d 30 mm
Overall length L 150 mm

Before ordering, check the actual conductor dimensions, conductor material, crimping tool and die set. Do not select the connector by model name alone. Send Trường Phát the required model, quantity and delivery information for specification checking and a quotation.

GT-400 copper connecting tube NEW

GT-400 copper connecting tube

The GT-400 copper connecting tube is a straight through-type connector used to join two copper cable ends by compression. This model has an outer diameter D of 34 mm, an inner diameter d of 26 mm and an overall length L of 130 mm. Its tubular construction allows the two prepared conductors to be inserted from opposite ends before compression with a compatible crimping tool and die.

Specification Value
Model GT-400
Product type Straight copper connecting tube
Material Copper
Outer diameter D 34 mm
Inner diameter d 26 mm
Overall length L 130 mm

Before ordering, check the actual conductor dimensions, cable material, die model and operating range of the crimping tool. Do not select the connector only by the cable’s overall outside diameter. Send the model, quantity and cable details to Truong Phat for specification checking and quotation support.

GT-300 copper connecting tube NEW

GT-300 copper connecting tube

The GT-300 copper connecting tube is a passing-through sleeve designed for inline cable jointing by compression. Its open tubular structure allows conductors to be inserted from opposite ends before the connection is compressed with a compatible tool and die. The model is identified by its catalogue dimensions, which should be checked against the actual conductor and the selected installation equipment.

Specification Value
Catalogue number GT-300
Product type Copper connecting tube, passing-through type
Outer diameter D 30 mm
Inner diameter d 24 mm
Overall length L 120 mm

Before ordering, compare the tube dimensions with the conductor, compression die and crimping tool used on site. Send Trường Phát the model, required quantity and cable details for product selection support and a quotation.

GT-240 copper connecting tube NEW

GT-240 copper connecting tube

GT-240 copper connecting tube is a through type copper connector designed for connecting suitable copper cables in electrical installation works. This model belongs to the GT Copper Connecting Tube (Passing Through Type) series, with dimensions of D 26mm, inner diameter d 21mm and length L 108mm according to the product catalog.

Specification Value
Model GT-240
Product type Copper Connecting Tube (Passing Through Type)
Outer diameter D 26 mm
Inner diameter d 21 mm
Length L 108 mm
Series GT-10 to GT-630

Before installation, check the cable cross-section and connection requirements to select the suitable connecting tube. Contact Truong Phat for consultation based on your cable specifications and quantity requirements.

GT-150 copper connecting tube NEW

GT-150 copper connecting tube

GT-150 copper connecting tube is a straight, pass-through connector designed to join two compatible copper cable ends by crimping. According to the dimensional table, the connector has a 22mm outer diameter, a 17mm inner diameter and an overall length of 94mm.

Before selection, compare the actual conductor diameter with the 17mm internal bore instead of treating the nominal cable cross-section as the conductor diameter. The conductor material, connector condition, crimping tool and die compatibility should also be checked before installation. Send the GT-150 model, cable details and required quantity to Truong Phat for specification checking and quotation support.

GT-120 Copper Connecting Tube

GT-120 Copper Connecting Tube

GT-120 Copper Connecting Tube is a through-type tubular connector designed to join two conductor ends using a suitable crimping method. According to the supplied dimensional chart, model GT-120 has an outer diameter D of 19mm, an inner diameter d of 15mm and an overall length L of 90mm.

Before selection, compare the actual conductor diameter with the 15mm internal bore and use a compatible crimping tool and die. Do not determine the suitable cable size from the model number alone. Submit the conductor type, actual core dimensions and required quantity for specification checking and quotation.

GT-95 Copper Connecting Tube

GT-95 Copper Connecting Tube

GT-95 Copper Connecting Tube is a passing through type copper cable connector used for electrical cable connection applications. This product belongs to the GT Copper Connecting Tube series, model GT-95, with technical dimensions including outer diameter D 18 mm, inner diameter d 14 mm and length L 81 mm.

Contact Truong Phat for consultation on selecting suitable cable connection accessories.

GT-70 copper connector

GT-70 copper connector

GT-70 copper connecting tube, full catalog number GT-1-70, is a passing-through straight connector designed for inline cable joints. According to the supplied dimensional table, the product has a 16 mm outer diameter, 12 mm inner diameter and 78 mm overall length.

  • Catalog number: GT-1-70
  • Design: Passing-through connecting tube
  • Outer diameter D: 16 mm
  • Inner diameter d: 12 mm
  • Overall length L: 78 mm
GT-50 copper connector

GT-50 copper connector

GT-50 copper connector is a through-type straight connecting tube designed to join two copper cable ends with a suitable nominal cross-sectional area of 50mm² by crimping. The model shown in the dimensional table is GT-1-50, with an outer diameter D of 13mm, an inner diameter d of 10mm and a length L of 70mm.

  • Model: GT-50
  • Suitable cable cross-sectional area: 50mm²
  • Outer diameter D: 13mm
  • Inner diameter d: 10mm
  • Length L: 70mm
GT-35 Copper Connecting Tube

GT-35 Copper Connecting Tube

GT-35 Copper Connecting Tube
GT-35 Copper Connecting Tube features an outer diameter of 11mm and inner diameter of 8mm
🏭 Overall tube length: 63mm, suitable for 35mm² copper cables
🛡️ Through-type construction allows easy positioning of both cable ends before crimping
🔧 Installed using a hydraulic crimping tool with the correct 35mm² die
📦 Multiple GT copper connector sizes are available for switchboards, factories, and projects
👉 Contact Truong Phat for stock checking, quotations, and suitable crimping die recommendations.

TRUONG PHAT ELECTROMECHANICAL EQUIPMENT COMPANY LIMITED
📍 No. 47, Adjacent Area 26, Van Phu Urban Area, Phu La, Ha Dong, Hanoi, Vietnam
📞 Hotline:

 

GT-25 Copper Connector

GT-25 Copper Connector

GT-25 Copper Connector Genuine
🔋 Suitable conductor size: 25mm²
GT-25 copper connector made from T2 copper with Cu content ≥ 99.9%
🏭 Reference dimensions: d = 7.1mm, D = 10mm, L = 60mm
🛡️ Through-hole design allows two cable ends to meet at the center of the tube
🔧 Installed using a mechanical or hydraulic crimping tool with the correct die size
📦 Suitable for switchboards, power cable systems and industrial electrical installations
👉 Contact Truong Phat to check availability and receive the latest GT-25 copper connector quotation. TRUONG PHAT ELECTROMECHANICAL EQUIPMENT COMPANY LIMITED
📍 No. 47, Adjacent Area 26, Van Phu Urban Area, Phu La, Ha Dong, Hanoi, Vietnam