NPP NP12-90Ah 12V 90Ah Battery

Product Categories

Product Search

Online Support

Mr Tài - 0869685636

Mr Tài - 0869685636

Ms Hồng - 0964602568

Ms Hồng - 0964602568

Ms Yến: 0984345846

Ms Yến: 0984345846

Ms Quỳnh: 0983607668

Ms Quỳnh: 0983607668

Selling Products

Fanpage Facebook

Statistical

  • Đang online 0
  • Hôm nay 0
  • Hôm qua 0
  • Trong tuần 0
  • Trong tháng 0
  • Tổng cộng 0
NPP NP12-90Ah 12V 90Ah Battery

NPP NP12-90Ah 12V 90Ah Battery

(1 đánh giá)

Ắc quy NPP NP12-90Ah 12V 90Ah

NPP NP12-90Ah 12V 90Ah Battery

  • 12V 90Ah AGM VRLA battery for stable backup power
  • Maintenance-free design, low self-discharge
  • Suitable for UPS, telecom, security, medical, and industrial systems
  • Compact structure, reliable standby service life

👉 Contact us now for technical consultation and the right battery solution for your backup power system.

NPP NP12-90Ah 12V 90Ah Battery – Reliable AGM Backup Power for Critical Systems ⚡

In backup power systems, choosing the right battery is not just about capacity. It is about stability, safety, service life, and how well the battery performs when the system needs instant DC power support. The NPP NP12-90Ah 12V 90Ah battery is a practical choice for engineers, contractors, and operators who need dependable standby power for important equipment.

Built in the General Purpose Series, this model uses AGM (Absorbent Glass Mat) technology and a valve-regulated lead-acid structure, making it suitable for many standby and general-purpose applications. The product sheet highlights its use in UPS, IT, security equipment, medical equipment, and standard equipment, which makes this battery especially relevant for electrical rooms, control systems, and backup installations.


🌟 Product Overview

The NPP NP12-90Ah is a 12V battery with 6 cells per unit and a nominal capacity of 90Ah at the 10-hour rate to 10.8V at 25°C. The datasheet also lists 95.4Ah at the 20-hour rate and 77Ah at the 5-hour rate, giving technicians a clearer basis for system sizing depending on discharge conditions.

From a practical installation perspective, this model is designed for systems that require stable standby DC power, low maintenance workload, and consistent operating behavior. With AGM construction, sealed design, and low self-discharge, it fits well in UPS cabinets, telecom racks, charger systems, and industrial auxiliary power setups.


✅ Key Advantages of the NPP NP12-90Ah

The strength of this battery is not only its 90Ah rating. It is the combination of build quality, standby life, charging parameters, and field-friendly installation features.

  • AGM VRLA design – sealed, clean, and suitable for standby applications
  • Maintenance-free operation – reduces routine service effort in installed systems
  • Low internal resistance: 5.0mΩ – supports stable performance under load
  • Low self-discharge: ≤3% per month at 25°C – useful for standby systems and stored inventory
  • Standby design life: 10 years by JIS at 25°C, 10/12 years by Eurobat at 20°C
  • Wide operating temperature range – adaptable to different electrical environments
  • Max charging current: 27A and max discharge current for 5 seconds: 800A for demanding system conditions

For engineering projects, these are the details that matter. A battery may look similar on paper, but charging voltage, internal resistance, terminal type, and actual capacity ratings often determine whether the system runs smoothly or causes repeated maintenance issues.


⚙️ Technical Specifications

Specification Value
Model NP12-90Ah
Battery type Valve-regulated lead-acid battery (AGM)
Nominal voltage 12V (6 cells per unit)
Nominal capacity 90Ah at 10-hour rate / 10.8V / 25°C
Capacity at 20-hour rate 95.4Ah
Capacity at 5-hour rate 77Ah
Terminal type T14
Terminal torque 5.1 ± 0.6 N.m
Approx. internal resistance 5.0mΩ at 25°C
Length 306 ± 2 mm
Width 169 ± 2 mm
Height 211 ± 2 mm
Total height 215 ± 2 mm
Weight 27.00 kg ± 3%
Nominal operating temperature 25°C ± 3
Discharge temperature range -15°C to 50°C
Charge temperature range -10°C to 50°C
Storage temperature range -20°C to 50°C
Float charging voltage at 25°C 13.5V – 13.8V
Cyclic charging voltage at 25°C 14.5V – 15.0V
Temperature compensation (float) -18 mV/°C/Block
Temperature compensation (cycle) -30 mV/°C/Block
Max. charging current 27A
Max. discharge current (5 seconds) 800A
Self-discharge rate ≤3%/month at 25°C
Container material ABS UL94-HB, V-0 optional
   

🧩 Construction Details

The datasheet lists the battery construction materials as follows:

  • Positive plate: Lead dioxide
  • Negative plate: Lead
  • Container: ABS (V-0 optional)
  • Separator: AGM
  • Electrolyte: Sulfuric acid
  • Safety valve: Rubber
  • Terminal: Copper

This structure is important in real-world use because it affects corrosion resistance, electrical conductivity, safety behavior, and long-term standby reliability.


🏭 Real Applications

The product sheet places this battery in the General Purpose Series and explicitly associates it with UPS, IT, security equipment, medical equipment, and standard equipment. That gives it a strong fit for many electrical and industrial backup applications.

Typical field applications include:

  • UPS backup systems
  • 🖥️ IT and network equipment
  • 🔐 Security and alarm systems
  • 🏥 Medical support equipment
  • 📡 Telecom backup power
  • 🛠️ Industrial control cabinets
  • 🔋 DC auxiliary power systems
  • ⚙️ Battery charger and inverter-integrated systems

👉 See related UPS solutions at: <a href="https://phukientudien.com.vn/bo-luu-dien-ups-435405s.html">UPS systems</a>
👉 See battery charger solutions at: <a href="https://phukientudien.com.vn/tu-sac-ac-quy-chinh-hang-441000s.html">Battery charger cabinets</a>
👉 Explore DC power solutions at: <a href="https://phukientudien.com.vn/bo-nguon-mot-chieu-dc-394940s.html">DC power supplies</a>


🔍 How to Choose the Right 12V 90Ah Battery

When selecting a battery for electrical works or industrial backup systems, do not look at Ah rating alone. A correct selection should match the actual operating profile of the system.

Checklist for choosing correctly:

  • Confirm the system DC voltage is 12V
  • Check whether the load is standby, cyclic, or mixed-duty
  • Review required backup time and actual discharge current
  • Verify battery dimensions: 306 x 169 x 211 mm, total height 215 mm
  • Confirm terminal type T14 matches the cable lug and hardware arrangement
  • Ensure the charger setting matches 13.5V–13.8V float or 14.5V–15.0V cyclic charging at 25°C
  • Consider ambient temperature, because battery life and performance are heavily affected by heat

Engineering note:
For standby cabinets and UPS rooms, wrong float voltage is one of the most common reasons batteries age early. For sites with unstable ambient temperature, temperature compensation should also be reviewed carefully.


🛠️ Installation and Usage Guide

To get stable service life from the NPP NP12-90Ah, installation should be done with standard electrical practice:

  • Install on a firm, ventilated surface
  • Use the correct terminal hardware for T14 terminals
  • Tighten connections to the recommended 5.1 ± 0.6 N.m
  • Check charger output before first commissioning
  • Do not exceed the 27A maximum charging current
  • Keep the battery bank within the recommended charge voltage range
  • Avoid long-term storage without maintenance charging

In practical projects, always recheck polarity, terminal cleanliness, and cable lug contact quality before energizing the system.


⚠️ Common Problems During Use

Every battery system can fail early if the installation or operating condition is wrong. For this model, the common technical mistakes usually come from charging and environmental control rather than from the battery itself.

  • Incorrect float voltage → battery swelling, heating, or short life
  • Loose terminal connection → voltage drop and terminal overheating
  • Oversized discharge demand → backup time shorter than expected
  • Poor ventilation → higher operating temperature and faster aging
  • Long storage without recharge → capacity loss due to deep self-discharge
  • Mismatch between charger and battery settings → unstable system performance

These are the points a site technician should inspect first before concluding the battery is defective.


❓ FAQ

1. Is the NPP NP12-90Ah a maintenance-free battery?
Yes. It is an AGM valve-regulated lead-acid battery, designed for maintenance-free operation in typical standby use.

2. What is the nominal voltage and capacity?
This model is 12V with a nominal capacity of 90Ah at the 10-hour rate to 10.8V at 25°C.

3. What charging voltage should be used?
At 25°C, the datasheet lists 13.5V–13.8V for float charging and 14.5V–15.0V for cyclic charging.

4. What are the battery dimensions?
The dimensions are 306 ± 2 mm x 169 ± 2 mm x 211 ± 2 mm, with total height 215 ± 2 mm.

5. What is the battery weight?
The battery weighs 27.00 kg ± 3%.

6. What is the self-discharge rate?
The self-discharge rate is ≤3% per month at 25°C.

7. What systems is this battery suitable for?
It is suitable for UPS, IT, security, medical equipment, and general-purpose standby applications.

8. What is the terminal type?
The terminal type is T14.


🎯 Call To Action

If you are looking for a 12V 90Ah AGM battery with stable performance, low self-discharge, and dependable standby service life, the NPP NP12-90Ah is a solid solution for professional backup power systems.

👉 Contact us now for technical advice, quotation, and project support on the right battery, charger, and UPS configuration for your application.

TRUONG PHAT ELECTRICAL EQUIPMENT CO., LTD
📍 Address: No. 47, Lane 26, Van Phu Urban Area, Phu La, Ha Dong, Hanoi

☎️ 📞 Hotline:
📌 Hotline: 0974.815.509-ZALO

📌 Khẩn cấp: 0869.685.636-Technical Support

🌐 Websites:
phukientudien.com.vn | codientruongphat.com
📩 Email: kinhdoanh3@truongphatme.com

Đánh giá sản phẩm

Bình chọn sản phẩm:

Sản phẩm cùng loại

NPP NP2-1000Ah 2V 1000Ah Battery

NPP NP2-1000Ah 2V 1000Ah Battery

NPP NP2-1000Ah 2V 1000Ah Battery

  • Nominal voltage 2V, capacity 1000Ah
  • Sealed AGM technology, low maintenance
  • Compact size, easy to install in UPS and electrical cabinets
  • Low self-discharge, stable performance
  • Suitable for UPS, fire alarm, emergency lighting, and telecom systems

👉 Contact us now for technical advice and the right NPP NP12-1000Ah 2V 1000Ah battery selection based on your load and backup time requirements.

NPP NP12-9Ah 12V 9Ah Battery for UPS, Fire Alarm, Emergency Light

NPP NP12-9Ah 12V 9Ah Battery for UPS, Fire Alarm, Emergency Light

NPP NP12-9Ah 12V 9Ah Battery for UPS, Fire Alarm, Emergency Light

  • Nominal voltage 12V, capacity 9Ah
  • Sealed AGM technology, low maintenance
  • Compact size, easy to install in UPS and electrical cabinets
  • Low self-discharge, stable performance
  • Suitable for UPS, fire alarm, emergency lighting, and telecom systems

👉 Contact us now for technical advice and the right NPP NP12-9Ah 12V 9Ah battery selection based on your load and backup time requirements.

NPP NP12-80Ah 12V 80Ah Battery – For UPS, Telecom & DC Power Systems

NPP NP12-80Ah 12V 80Ah Battery – For UPS, Telecom & DC Power Systems

NPP NP12-80Ah 12V 80Ah Battery – For UPS, Telecom & DC Power Systems

  • 12V nominal voltage, 80Ah rated capacity
  • Sealed AGM technology, maintenance-free design
  • Up to 10 years design life
  • Low self-discharge, ideal for standby systems
  • Suitable for UPS, telecom, fire alarm, medical devices, and DC power cabinets

👉 Contact us now for technical support and the right NPP NP12-80Ah battery solution for your actual backup time requirements

NPP NP12-7Ah Battery – 12V 7Ah AGM Battery for UPS & Fire Alarm

NPP NP12-7Ah Battery – 12V 7Ah AGM Battery for UPS & Fire Alarm

NPP NP12-7Ah Battery – 12V 7Ah AGM Battery for UPS & Fire Alarm

  • 12V nominal voltage and 7Ah rated capacity
  • AGM sealed lead-acid design, maintenance-free
  • Compact size, suitable for UPS, fire alarm, and backup systems
  • Low self-discharge and stable standby performance

👉 Contact us now for technical support and the right NP 12V 7Ah NPP battery solution for your system

NPP 12V 60Ah AGM Battery – For UPS, Telecom & Industrial Backup Power

NPP 12V 60Ah AGM Battery – For UPS, Telecom & Industrial Backup Power

NPP 12V 60Ah AGM Battery – For UPS, Telecom & Industrial Backup Power

  • 12V 60Ah battery suitable for many backup power systems
  • Sealed AGM technology for stable operation and low maintenance
  • Low self-discharge rate of around 3% per month at 25°C
  • Ideal for UPS, telecom, fire alarm, medical, and industrial electrical systems

👉 Contact us now for technical support and the right NPP 12V 60Ah battery recommendation for your actual load demand.

Genuine NPP 12V 55Ah Battery

Genuine NPP 12V 55Ah Battery

Genuine NPP 12V 55Ah Battery

  • 12V voltage, 55Ah capacity, suitable for many backup power systems
  • Sealed AGM technology, stable operation, low maintenance
  • Low self-discharge, around 3% per month at 25°C
  • Ideal for UPS, fire alarm, telecom, medical equipment, and power stations

 

👉 Contact us now for technical advice on choosing the right NPP 12V 55Ah battery for your actual load and backup time requirements.

NPP 12V 50Ah Battery – Stable Backup Power, Durable and Safe

NPP 12V 50Ah Battery – Stable Backup Power, Durable and Safe

NPP 12V 50Ah Battery – Stable Backup Power, Durable and Safe

  • Rated voltage: 12V
  • Rated capacity: 50Ah
  • AGM sealed lead-acid design
  • Suitable for UPS, fire alarm, security, telecom, and backup power systems
  • Low self-discharge and reliable long-term standby performance

👉 Contact us for technical support and the right battery selection for your system.

NPP 12V 45Ah Battery – Stable

NPP 12V 45Ah Battery – Stable

NPP 12V 45Ah Battery – Stable

  • Rated voltage: 12V
  • Rated capacity: 45Ah
  • AGM sealed lead-acid design
  • Suitable for UPS, fire alarm, security, telecom, and backup power systems
  • Low self-discharge and reliable long-term standby performance

👉 Contact us for technical support and the right battery selection for your system.

NPP 12V 35Ah Battery NP12-35Ah – Specifications, Applications & Features

NPP 12V 35Ah Battery NP12-35Ah – Specifications, Applications & Features

NPP 12V 35Ah Battery NP12-35Ah – Specifications, Applications & Features

  • Rated voltage: 12V
  • Rated capacity: 35Ah
  • AGM sealed lead-acid design
  • Suitable for UPS, fire alarm, security, telecom, and backup power systems
  • Low self-discharge and reliable long-term standby performance

👉 Contact us for technical support and the right battery selection for your system.

12V 26Ah NPP Battery – UPS & Telecom Use

12V 26Ah NPP Battery – UPS & Telecom Use

🔋 NPP 12V – 26Ah AGM battery, sealed and maintenance-free, ideal for UPS, telecom, and backup systems.

✔️ Stable voltage output
✔️ Low self-discharge
✔️ Long service life
✔️ Reliable in harsh environments

👉 Contact us now for the right configuration & fast quotation!

NPP 12V 250Ah Battery NP Series | AGM Sealed Lead Acid

NPP 12V 250Ah Battery NP Series | AGM Sealed Lead Acid

NPP 12V 250Ah Battery NP Series | AGM Sealed Lead Acid

  • Maintenance-free AGM sealed battery
  • High capacity 250Ah for industrial systems
  • Long design life up to 10–12 years
  • Strong discharge performance for UPS & telecom
    👉 Contact us now for quick consultation & quotation
NPP 12V 20Ah AGM Battery Genuine Product

NPP 12V 20Ah AGM Battery Genuine Product

NPP 12V 20Ah AGM Battery Genuine Product

  • AGM sealed lead-acid design, safe and maintenance-free
  • 12V / 20Ah capacity for many backup power applications
  • 🏭 Suitable for UPS, fire alarm systems, telecom, and medical devices
  • 📦 Compact size for easy installation in cabinets and backup systems
  • ✅ Low self-discharge and stable performance for general-purpose standby use

👉 Contact us now for quick advice on choosing the right battery model for your load and backup time requirements.

Top

   (0)