10A DC MCB ADB3-63DC Genuine Premium Deal

Product Categories

Product Search

Online Support

Mr Tài - 0869685636

Mr Tài - 0869685636

Ms Hồng - 0964602568

Ms Hồng - 0964602568

Ms Yến: 0984345846

Ms Yến: 0984345846

Ms Quỳnh: 0983607668

Ms Quỳnh: 0983607668

Selling Products

Fanpage Facebook

Statistical

  • Đang online 0
  • Hôm nay 0
  • Hôm qua 0
  • Trong tuần 0
  • Trong tháng 0
  • Tổng cộng 0
10A DC MCB ADB3-63DC Genuine Premium Deal

10A DC MCB ADB3-63DC Genuine Premium Deal

(1 đánh giá)

át-tô-mát một chiều DC 10A

ANDELI ADB3-63DC C10 Genuine | 10A DC MCB for DC Panels
🔋 2P - 10A, protects both poles in direct current circuits.
500V DC - Icn 6000A, C curve for common DC loads.
🏭 Suitable for solar PV, batteries, DC panels, electric vehicles and industrial projects.
🛡️ Energy limiting class T4, compliant with GB/T10963.2 and IEC 60898-2.
🔧 Quick DIN rail 35mm installation, compact 2-module structure for electrical panels.
📦 Genuine product, CO-CQ documents available upon customer request.
👉 Contact us for a fast quotation:

📞 Technical consultation hotline:

 

 

ANDELI ADB3-63DC C10 Genuine 10A DC MCB for Solar PV and DC Panels

ANDELI ADB3-63DC C10 is a 10A DC MCB designed for switching and overcurrent protection in direct current circuits. This 2P device is rated at 500V DC, has a 6000A breaking capacity, and mounts directly on a 35mm DIN rail. With a C tripping curve, the 10A DC MCB is suitable for solar PV systems, battery circuits, DC control panels, and auxiliary direct current power branches.

📌 Table of Contents

⚡ Technical Specifications of ANDELI ADB3-63DC C10

Item Value
Brand ANDELI
Model ADB3-63DC
Device Type Miniature circuit breaker for direct current DC circuits
Number of Poles 2P
Rated Current 10A, marked C10
Tripping Curve C curve, magnetic trip from 5-10 x In
Rated Voltage 500V DC
Main Rating 10A, 2P, Icn 6000A, energy limiting class T4
Technology/Material Modular DC MCB, 35mm DIN rail mounting; enclosure material
Breaking Capacity 6000A
Module Width 2 modules, 1 module per pole, 18mm per module
Standards GB/T10963.2, IEC 60898-2
Certifications CCC, CE
Applications Solar PV systems, batteries, DC panels, electric vehicles

🔋 Key Features of ANDELI ADB3-63DC C10

  • ✔️ The 10A DC MCB has a 2P configuration, suitable for isolating both positive and negative poles in a DC circuit.
  • ✔️ Rated at 500V DC, this device is built for direct current applications and should not be confused with a standard AC MCB.
  • ✔️ The 6000A breaking capacity supports fault interruption within the designed short-circuit range of the system.
  • ✔️ C curve tripping is practical for loads with short inrush current, often seen in DC power supplies, converters, and control loads.
  • ✔️ The compact 2-module design fits 35mm DIN rails, making installation easier in solar combiner boxes, battery cabinets, and DC control panels.

A critical point when choosing a 10A DC MCB is DC arc interruption. Direct current has no natural zero-crossing point like AC, so the protective device must be rated for DC voltage and DC switching duty.

🏭 Practical Applications of ANDELI ADB3-63DC C10

With a 10A rated current and 500V DC voltage rating, the ANDELI ADB3-63DC 10A DC MCB is commonly installed on individual protection branches in direct current systems.

  • 🔧 Protection of DC branches in residential and light industrial solar PV systems.
  • 🔧 Installation inside battery cabinets, charger panels, or DC auxiliary supply branches.
  • 🔧 Switching and protection at the input or output of DC power supplies, chargers, and DC converter modules.
  • 🔧 Use in telecom DC cabinets, automation control panels, and backup DC power systems.
  • 🔧 Suitable for electric vehicle auxiliary circuits or DC testing benches when voltage, current, and fault-current ratings match the design.

When building a DC panel, technicians can combine the 10A DC MCB with DC power supplies, neutral and grounding bars, and terminal blocks for cleaner wiring inside the cabinet.

🔧 Benefits of Using ANDELI ADB3-63DC C10

Selecting the correct 10A DC MCB helps the system operate more safely, especially in DC branches where arc risk may occur during switching or short-circuit faults.

  1. Reduces the risk of using an AC MCB incorrectly in a DC circuit.
  2. Allows quick isolation of a 10A branch during maintenance, module replacement, or wiring inspection.
  3. Supports compact panel layout thanks to its 2-module DIN rail structure.
  4. Provides overload and short-circuit protection for DC supply branches with suitable operating current.
  5. Easy to replace and stock as spare parts because DIN rail mounting is widely used in industrial electrical panels.

📋 Selection Guide for ANDELI ADB3-63DC C10

When selecting a 10A DC MCB, the first step is to confirm that the maximum open-circuit or supply voltage does not exceed the 500V DC rating of the device. Continuous load current should be calculated based on power, cable size, panel temperature, and actual wiring conditions.

For solar PV applications, check the string short-circuit current, correction factors, installation conditions, and two-pole isolation requirement. For battery panels, review discharge current, charging current, prospective short-circuit current, and coordination with upstream fuses or protective devices.

In DC power cabinets, the 10A DC MCB can be used with 12VDC 24VDC battery chargers or sealed lead-acid batteries to form a safer backup power system. For standard references, engineers should also review IEC requirements and project technical documents before final model selection.

🏢 Why Buy ANDELI ADB3-63DC C10 from Truong Phat?

  • ✔️ Genuine products with clear origin.
  • ✔️ Professional solution consulting.
  • ✔️ Support for installation and system wiring.
  • ✔️ Competitive pricing and fast quotation.
  • ✔️ Technical support throughout product use.

Truong Phat supplies the 10A DC MCB for panel assembly, DC system maintenance, and project spare-part needs. Our technical team can help verify the 2P, 500V DC, and Icn 6000A specifications to avoid incorrect device selection in actual cabinet drawings.

❓ Frequently Asked Questions about ANDELI ADB3-63DC C10

🔹 Can ANDELI ADB3-63DC C10 be used for AC circuits?

ADB3-63DC C10 is specified as an MCB for direct current DC circuits. For AC systems, engineers should select the correct AC MCB series based on the catalogue and panel standards, instead of substituting devices across applications.

🔹 Is this 10A DC MCB suitable for solar PV systems?

Yes, the device is intended for solar PV applications. However, the PV string voltage, operating current, short-circuit current, and branch protection requirement must be checked before installation.

🔹 Why does a DC circuit need a dedicated DC MCB?

DC arcs are harder to extinguish than AC arcs because current does not naturally cross zero in every cycle. Therefore, a 10A DC MCB must be designed for direct current operation and rated for the correct DC voltage.

🔹 Does the ADB3-63DC C10 take much space inside a panel?

The device has a 2-module structure, with each pole occupying 18mm, and installs on a 35mm DIN rail. This makes it practical for compact DC panels, solar combiner boxes, and branch protection sections.

🔹 When should I choose 10A instead of 16A or 20A?

Choose 10A when the load current, cable size, and branch protection requirement match the C10 rating. For larger loads or different inrush behavior, the circuit must be recalculated to avoid nuisance tripping or insufficient protection.

📞 Quotation for ANDELI ADB3-63DC C10

The price of the ANDELI ADB3-63DC 10A DC MCB depends on order quantity, import timing, CO-CQ document requirements, and delivery schedule. To receive the correct quotation for C10, 2P, 500V DC, customers should send the required quantity, product label photo, or the electrical cabinet drawing.

Truong Phat provides fast consultation for customers replacing DC MCBs or assembling solar PV panels, battery cabinets, and direct current power systems. For project orders, we can quote by batch to optimize electrical material cost.

TRUONG PHAT MECHANICAL ELECTRICAL EQUIPMENT COMPANY LIMITED
📍 Address: No. 47, Adjacent House 26, Van Phu Urban Area, Phu La, Ha Dong, Hanoi, Vietnam

📞 Technical consultation hotline:

🌐 Website:

📧 Email: kinhdoanh3@truongphatme.com

ANDELI ADB3-63DC C10 is a reliable 10A DC MCB solution for DC branches that require clear protection, convenient switching, and safer operation inside electrical panels.

 

Đánh giá sản phẩm

Bình chọn sản phẩm:

Sản phẩm cùng loại

DC Circuit Breaker 50A ADB3 Genuine Premium Deal

DC Circuit Breaker 50A ADB3 Genuine Premium Deal

ANDELI ADB3-63DC DC Circuit Breaker 50A Genuine | Reliable 500V DC Protection
🔋 50A C50 DC circuit breaker, suitable for medium DC branch protection.
500V DC, 2P, designed for direct current electrical systems.
🏭 Suitable for solar PV, battery systems, DC panels, EV applications and industrial projects.
🛡️ 6000A breaking capacity, supports safe isolation during DC short-circuit faults.
🔧 Quick installation on 35mm DIN rail, compact 2-module design for control cabinets.
📦 Genuine product, CO-CQ documents available upon customer request.
👉 Contact for fast quotation:

📞 Technical consultation hotline:

 

DC circuit breaker 40A

DC circuit breaker 40A

ANDELI ADB3-63DC DC Circuit Breaker 40A Genuine | Reliable Protection For 500V DC Systems
🔋 40A - C40 DC circuit breaker 40A, suitable for DC branch circuits, battery banks and DC panels.
500V DC - 2P, C tripping curve, 6000A rated breaking capacity.
🏭 Suitable for solar PV, DC cabinets, battery systems, EV auxiliary circuits and industrial projects.
🛡️ Designed according to GB/T10963.2 and IEC 60898-2, with CCC and CE certification.
🔧 Quick DIN 35mm rail mounting, compact 2-module design for electrical cabinets.
📦 Genuine product, CO-CQ documents available upon customer request.
👉 Contact for fast quotation:

📞 Technical hotline:

 

32A DC circuit breaker

32A DC circuit breaker

ANDELI ADB3-63DC 32A DC Circuit Breaker Official | Reliable 500VDC Protection
🔋 32A C32, suitable for DC branch circuits, battery cabinets and solar PV systems.
500V DC, 2P DC MCB technology for disconnecting both poles safely.
🏭 Suitable for solar PV, battery systems, DC cabinets and industrial projects.
🛡️ 6000A breaking capacity helps isolate overcurrent and short-circuit faults.
🔧 Quick DIN 35mm rail mounting, compact 2-module width for electrical panels.
📦 Genuine product, CO-CQ documents available upon customer request.
👉 Contact us for a fast quotation:

📞 Technical consultation hotline:

 

20A DC circuit breaker

20A DC circuit breaker

20A DC Circuit Breaker ANDELI ADB3-63DC Genuine | 500V DC Protection
🔋 20A C20, 2P, suitable for disconnecting both poles in DC circuits.
500V DC, Icn 6000A, DC MCB technology according to IEC 60898-2.
🏭 Suitable for solar PV, battery banks, DC panels, EV systems and industrial projects.
🛡️ T4 energy limiting class helps reduce thermal impact during short-circuit faults.
🔧 Quick installation on 35mm DIN rail, compact 2-module design.
📦 Genuine product, CO-CQ documents available upon customer request.
👉 Contact for fast quotation:

📞 Technical consultation hotline:

 

Top

   (0)